Applications and Setups 5
DG711 and DG511 Pipe Laser User Guide 41
Setting Line 5.4.6
The principle for setting line is
always the same. The laser is
positioned over the starting point
of the pipe run then aimed to the
second control point on line. The
further your second point is from
the laser, the more accurate your
line will be.
First Point Setup (Using
Plumb-bob) 5.4.7
Whether using the laser in the
invert or attached to the various
mounting plates the goal is to
always set the laser’s line axis
bull’s-eye target over the vertical
centerline of the pipe.
Step 5 Subtract the desired elevation of laser
beam above the pipe’s invert.
-0.152 m -0.50 ft
Step 6 Subtract beam offset (70 mm / 0.23 ft). -.070 m -0.23 ft
Step 7 Calculated Rod Reading = 0.805 m
1.128 m
-0.152 m
-0.070 m
1.711 m
2.64 ft
3.70 ft
-0.50 ft
-0.23 ft
5.61 ft
Step 8 Set the rod on top of the Laser and
adjust elevation until the correct rod
reading is observed.
1.711 m 5.61 ft
Step 9 The laser beam is now set at your desired working elevation
(152.4 mm / 6 inches / 0.5 ft) above the invert of the proposed
pipe.
Table 5.3 Example 2: Setting Grade Rod on Top of Laser
Step Description Metric Ft / Inch